Keep measured consumption separate from estimates

Power in kW describes the kiln's demand under a particular condition; energy in kWh describes consumption accumulated over time. Rated power and program duration alone do not always describe actual energy use.

A controller's displayed figure may be calculated from configured power and element-on time. Check its manual to establish whether the figure is measured or estimated.

Illustrative calculation
Available informationHow to use it
kWh recorded by a meter dedicated to the cycleUse it to calculate electricity cost for that cycle.
kWh estimated by the controllerKeep the figure labeled as estimated and check the configured parameters.
Rated power and durationBuild an estimate and state the assumed share of element-on time.
Only the studio's total electricity billSeparate other consumption before allocating an amount to the kiln.

Example using measured energy

For this example only, suppose a dedicated meter records 45 kWh and the chosen electricity rate is €0.30/kWh. Electricity cost is 45 × 0.30 = €13.50. These are illustrative figures, not a current tariff or a typical kiln's consumption.

Use a rate consistent with the firing period and with the costs you intend to allocate to electricity. If the rate changes during the cycle and consumption is available by time band, calculate each part separately and add the results. Do not count fixed charges twice if they are already allocated to studio overhead.

If you only know rated power and duration

A simplified estimate is: estimated energy = rated power × duration × element-on fraction. The fraction is the share of time during which the elements are assumed to draw the stated power.

In a separate example: 6 kW × 10 hours × 0.60 = 36 kWh. At the hypothetical rate of €0.30/kWh, estimated electricity cost is €10.80. The 0.60 factor is an educational assumption, not a universal value. Program, load and kiln conditions can change the result; compare the estimate with available measurements.

From electricity to a fuller firing cost

Return to the first example using 45 kWh. Add hypothetical labor and wear costs. The result is a cost calculated from these items, not a fee to charge customers automatically.

Illustrative calculation
ItemCalculationCost
Electricity45 kWh × €0.30/kWh€13.50
Loading and unloading30 minutes × €18.00/hour€9.00
Share of wear and maintenanceAssumption for this firing€3.00
Total of the items included€13.50 + €9.00 + €3.00€25.50

If the load contains 30 equivalent pieces and all are successful, the allocated cost is €25.50 ÷ 30 = €0.85 per piece. Materials, making, glazing, packaging and other studio expenses are excluded from this total.

Mixed loads and shared firings

Dividing by the piece count is a simple method when pieces occupy comparable space. For very different sizes, you can choose shares based on the space allocated in the load. State the method and allocate 100% of the cost overall.

Here is another illustrative load with the same €25.50 total cost: 10 mugs assigned 1 share each and 5 bowls assigned 3 shares each. The 25 shares are an example costing method, not instructions for loading a kiln.

Illustrative calculation
GroupTotal sharesShare of costGroup costCost per piece
10 mugs × 1 share1040%€10.20€1.02
5 bowls × 3 shares1560%€15.30€3.06
Total25100%€25.50—

Sharing a firing allocates its cost among participants. To claim savings against separate firings, you need comparable records of loads, programs and energy use. The number of participants alone does not establish savings.

Bisque, glaze firings and rejected pieces

Calculate each cycle separately and allocate to a piece only the firings it actually received. Piece counts and occupied space may change between bisque and glaze firings.

Record losses as pieces that cannot be sold. If 3 of the 30 equivalent pieces are rejected after firing, the €25.50 incurred is allocated to 27 saleable pieces: €25.50 ÷ 27 is approximately €0.94 per piece. Keep full precision in calculations and round only the amounts displayed.

Use your kiln information in LUXCERIVO

Free provides an initial estimate using standard kilns. Pro and Suite, currently available as previews for registered users, describe an extended kiln catalog and custom configurations.

Estimates help compare batch assumptions. They are not an automatic meter reading and do not replace measured consumption or material technical data sheets. Payments and licenses are not active.

Method and sources

All amounts, loads and timings on this page are original illustrative examples. The arithmetic is shown so that results can be checked.

Skutt's documentation explains the estimation principle using power, duration and element-on time. For values specific to your kiln, use its manual and your own firing records. LUXCERIVO feature availability refers to public page v0.12.38, checked on 22 November 2026.

Common questions

Does a 6 kW kiln always use 6 kWh each hour?

A constant draw of 6 kW for one hour equals 6 kWh. During a program, power may vary or the elements may cycle on and off. Use measured consumption when available.

Is electricity the whole firing cost?

No. A fuller cost can include loading and unloading, wear, maintenance and other relevant items. State what the total includes and avoid counting costs already included elsewhere.

Can I divide the cost by every piece in the load?

Yes, if that is your chosen method and the pieces are comparable. For very different shapes, consider explicit shares, for example based on allocated space. When costing saleable pieces, account for actual losses too.

Does LUXCERIVO measure the kiln's electricity use?

The features described here produce estimates from entered data. Automatic consumption measurement is not described. Compare estimates with your meter or controller records, distinguishing measured figures from calculated ones.

Sources and method